2640.5 €2,640.50 Excl. VAT
Loading stock info
  •  
Product number: ELE006484

Be the first to review this product

Details

The Tekbox TBMDA-BCI25 modulated power amplifier provides the necessary modulation and bandwidth for accurate immunity testing (per ISO 11452-4) with BCI probes. Designed to be driven by a signal generator, a tracking generator (through the internal AM / PM - modulator) or a spectrum analyser, it can generate test levels up to 400mA in the frequency range of 1 MHz to 400 MHz.

Furthermore, it has sufficient gain to achieve maximum output power with 0 dBm provided by a spectrum analyser tracking generator. In PM mode, the amplifier can also generate a 217 Hz signal with 12.5% duty cycle in order to simulate mobile phone TDMA noise.

Model overview

Model TBMDA-BCI25 TBMDA-BCI100
Maximum output power @ Pin = 0 dBm 1 MHz - 44.2 dBm (26.3 W) typ.
100 MHz - 45.0 dBm (31.6 W) typ.
400 MHz - 44.6 dBm (28.8 W) typ.
1 MHz - 50.7 dBm (117.5 W) typ.
100 MHz - 50.7 dBm (117.5 W) typ.
400 MHz - 49.5 dBm (89.1 W) typ.
1 dB output compression point 1 MHz - 43.3 dBm typ.
100 MHz - 44.1 dBm typ.
400 MHz - 44.0 dBm typ.
1 MHz - 50.5 dBm typ.
100 MHz - 50.7 dBm typ.
400 MHz - 48.6 dBm typ.
Harmonics 2nd harmonic, 100 MHz, Pout = 45.7 dBm: < -23 dBc typ.
2nd harmonic, 100 MHz, Pout = 40 dBm: < -29 dBc typ.
3rd harmonic, 100 MHz, Pout = 45.7 dBm: < -12 dBc typ.
3rd harmonic, 100 MHz, Pout = 40 dBm: < -19 dBc typ.
2nd harmonic, 100 MHz, Pout = 44.0 dBm: < -20.2 dBc typ.
2nd harmonic, 100 MHz, Pout = 50.0 dBm: < -16.3 dBc typ.
3rd harmonic, 100 MHz, Pout = 44.0 dBm: < -12.2 dBc typ.
3rd harmonic, 100 MHz, Pout = 50.0 dBm: < -11.9 dBc typ.
Price 2640.5 €2,640.50 Excl. VAT 4450 €4,450.00 Excl. VAT

Specifications

Max. input power+0 dBm
Frequency range1 MHz - 400 MHz
Internal modulation frequencyAM: 1 kHz ±20%
PM: 1 kHz ±20%, 217 Hz ±20%
Duty cycle (PM)1 kHz - 50% ±10%, 217 Hz - 12.5% ±20%
Dimensions320 x 280 x 120 mm

Accessories

The Tekbox TBMDA-BCI25 comes with:

  • 2x 75 cm N-Male to N-male cables
  • 1x 6dB attenuator
  • 1x 30dB/50W attenuator with N-connectors
  • Power cord

Pros and cons

  • Conducted immunity testing with BCI-probes
  • Radiated immunity testing with near-field probes
  • Mobile phone TDMA noise simulation
  • Can be damaged by open or shorted loads

Downloads