1490 €1,490.00 Excl. VAT
Loading stock info
  •  
Product number: ELE006002

Be the first to review this product

Details

The Tekbox TBBCI1-800K420 is a bulk current injection probe characterized in the frequency range of 10 kHz to 500 MHz. The CBI probe is designed for immunity testing of automotive products according to ISO 11452-4 and IEC/ EN 61000-4-6 standards (1 MHz - 400 MHz), and in the frequency range 250 kHz - 230 MHz it is compliant with their insertion loss specifications. The insertion loss of the probe is 5 dB for most of its bandwidth, and it is possible to inject severity levels I (60 mA), II (100 mA), III (150 mA), IV (200 mA) and customer specific severity level V up to 350 mA. At last, the TBBCI1-800K420 can also be used for monitoring purposes.

We also sell the calibrator fixture for the TBBCI1-800K420 probe, the TBBCI1-CAL.

Model overview

Currently we have three Tekbox models in our catalogue, which differ in terms of their frequency range, compliant standards, and connector type.

Model TBBCI1-200K280 TBBCI1-800K420 TBBCI1-300K420HV
Frequency range 10 kHz - 300 MHz 10 kHz - 500 MHz 10 kHz - 500 MHz
Compliant standards IEC/ EN 61000-4-6 ISO 11452-4 & IEC/ EN 61000-4-6 ISO 11452-4, MIL-STD-461G CS114, GJB 151B-2013, DO-160 sec. 20 & 22
Insertion loss (typ.) 8 dB 5 dB 5 dB
Connector N female N female BNC-SHV male
Price 1490 €1,490.00 Excl. VAT 1490 €1,490.00 Excl. VAT 1845 €1,845.00 Excl. VAT

Specifications

Transfer impedance 29 dBΩ typ.
Power rating Severity levels I, II, III, IV (according to ISO 11452)
Customer specified level V up to 350 mA
Aperture diameter 27 mm
Connector N female
Outer dimensions Diameter: 92 mm
Height: 76 mm
Weight 1.2 kg

Downloads